Features
l 21.5 inch LED screen, with Li-battery backup
l PW, CW, DPDI, THI, Compound Imaging, real-time 3D/4D
l 2B/4B Imaging Modes
l Color Doppler 128 elements, Win 8, 128GB SSD.
l Support: Chinese/ English/ Spanish/ French/ Russian
l All-in-one clipboard: saved images display on the bottom of the screen, which can be directly transferred or deleted.
l Interface: 2*USB; 1*Video; 1*S-Video; 1*DVI; 1*HDMI; 1*RJ-45
Technical Specifications
PARAMETER | SPECIFICATION |
2D Imaging Mode | |
Gain | 0-100, Step 1 adjustable |
TGC | 8 segment adjustable |
Dynamic | 20-280, 20 levels adjustable |
Pseudo color | 0-11, adjustable |
Sound power | 5%-100%, step 5% adjustable |
Body mark | ≥18 kinds optional |
Maximum focus | ≥6, which can be moved throughout the whole process |
Grey scale map | 0-7, 7 levels adjustable |
Filter | 0-4 |
Scanning range | 50%-100% |
Frame correlation | 0-4, 4 level adjustable |
Line density | low, middle, high, 3 levels adjustable |
Noise reduction | 0-14 |
The screen has real-time display of sound power, probe frequency, dynamic range, pseudo color, gray scale and other 14 parameters can be adjusted. | |
Color Doppler Imaging Mode | |
Color Frame correlation | 0-12, 12 levels adjustable |
Color map | 0-7, 7 levels adjustable |
Color flip | adjustable |
Base line | 11 levels, adjustable |
Line density | low, high, 2 levels adjustable |
Filter | 0-5 levels adjustable |
B / C real-time split screen mode | |
Spectral Doppler Imaging Mode | |
Sampling volume angle correction | -80°~80°adjustable |
Sample volume | 0.5mm-20mm adjustable |
Frequency | 2.5MHz, 3.0MHz |
Base line | 11 levels, adjustable |
Pseudo color | 0-5 |
Parameter display | ≥4 kinds, adjustable |
Speed scale | 32.8-328cm/s (different probes have different ranges) |
Spectrum envelope function | real time automatic spectrum envelope, manual spectrum envelope, and other. The system automatically analyses and displays various data such as PS, ED, RI, PI, S/D, HR, etc. |
Grey map | 0-7 |
Filter | 0-8 |
Dynamic range | 10-95, step 5 |
Noise reduction | 0-28 |
Sound volume | 0-100 |
3D Imaging (optional) | |
Fast angle | supports 0°, 90°, 180°, 270° rotation for 3D View |
Display mode | one image, two images, four images |
Reconstruction mode | Real Skin, Surface, Max, Min, X Rax |
Pseudo color | 0-7, 7 levels adjustable |
Zoom | 5 levels |
Contrast | 0%-100% |
Threshold level | 0%-100% |
Smooth | ≥3 levels |
Image rotation | X/Y/Z Axis |
Brightness | 0%-100% |
4D Imaging (optional) | |
Fast angle | supports 0°, 90°, 180°, 270° rotation for 3D View |
Display model | one image, two images, four images |
Reconstruction mode | Real Skin, Surface, Max, Min, X Rax |
Pseudo color | 0-7, 7 levels adjustable |
Zoom | 5 levels |
Contrast | 0%-100% |
Threshold level | 0%-100% |
Smooth | ≥3 levels, adjustable |
Image rotation | X/Y/Z Axis |
Line density | 2 levels, adjustable |
Various Probes
l Convex probe (detecting depth: 30-255mm)
Fundamental Frequency: 2.5MHz/ 3.0MHz/ 3.5MHz/ 4.0MHz
Harmonic Frequency: H4.0MHz/ H5.0MHz
l Linear probe (detecting depth: 20-128mm)
Fundamental Frequency: 6.0MHz/ 7.5MHz/ 8.5MHz/ 10.0MHz
Harmonic Frequency: H10.0MHz
l Micro-convex probe R15 (detecting depth: 30-111mm)
Fundamental Frequency: 4.0MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz
Harmonic Frequency: H8.0MHz
l Phased array probe (detecting depth: 100-244mm)
Fundamental Frequency: 2.5MHz/ 3.0MHz/ 3.5MHz/ 4.0MHz
Harmonic Frequency: H3.0MHz/ H4.0MHz
l Micro-convex probe R11 (detecting depth: 30-111mm)
Fundamental Frequency: 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz
Harmonic Frequency: H8.0MHz
l 4D volume probe (detecting depth: 30-237mm)
Fundamental Frequency: 2.0MHz/ 3.0MHz/ 4.5MHz/ 6.0MHz
Harmonic Frequency: H5.0MHz
l Rectal linear probe (detecting depth: 30-156mm)
Fundamental Frequency: 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz
Harmonic Frequency: H8.0MHz
Graphic and Text Management System
l Host build in 128G hard disk, start fast and stable.
l Movie playback: ≥600 frames.
l Report type: ≥6.
l One key fast report graphic and text management.
l Image format: BMP, DCM, JPG.
l Internal file information management system: can record patient number, name, check number, check date and so on, and can be searched and managed by number, check number, name and so on.